Heat pumps · MT

Tecalor TTL 4.5 ICS

The Tecalor TTL 4.5 ICS is an air-to-water heat pump with a SCOP of 4.53 (35 °C) and a sound power level of 32 dB(A).1,2,3

Key figures

SCOP (35 °C)
4.533

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Heating capacity (A7/W35)
2.06kW2
Official source
Outdoor unit sound power
32dB(A)3
Official source
Refrigerant
R410A1
Official source
Type (source)
Air-to-water1
Official source
MT

Rules in Malta

Water Heater Scheme (heat pump water heaters)

Unknown

REWS runs a national grant scheme for energy-efficient water heaters in homes; heat pump water heaters are eligible (alongside solar water heaters). The scheme has been extended to 31 December 2026, and part A of the application must be submitted before you buy and install the equipment. Grant amounts: see the REWS page (not verified by us).

Technical specifications

General
Type (source)Air-to-water1
Compressors11
Capacity controldrehzahlregelung1
Performance
Heating capacity (A7/W35)2.06 kW2
Rated output 35 °C5 kW3
Rated output 55 °C4 kW3
Min. outdoor temperature-20 °C2
Efficiency
SCOP (35 °C)4.533
SCOP (55 °C)3.333
Seasonal efficiency ηs 35 °C178 %3
Seasonal efficiency ηs 55 °C130 %3
Energy label 35 °CA+++3
Energy label 55 °CA++3
COP A7/W354.681
COP A2/W353.831
COP A-7/W353.161
Noise
Outdoor unit sound power32 dB(A)3
Indoor unit sound power45 dB(A)3
Refrigerant
RefrigerantR410A1
Refrigerant GWP2,0882
Refrigerant charge2.2 kg1
Electrical
Max. power input8.5 kW1
Connectivity & smart
SG ReadyYes1

How it ranks

SCOP (35 °C): better than 18% of comparable models in our database (Heat pumps · Air-to-water · 4–6 kW; n = 114).

Rank 92 of 115

Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.

Compare with

Similar models

Other brands, same type and a comparable size.

More from Tecalor

All Tecalor models (57) →

Featured in these lists

How we collect and check this data →

Frequently asked questions

Which refrigerant does the Tecalor TTL 4.5 ICS use?

The Tecalor TTL 4.5 ICS uses R410A.1,2,3

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 29 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 18 Oct 2026
  4. Water Heater Scheme (heat pump water heaters) — Regulator for Energy and Water Services (REWS)