Heat pumps · MT

OUTES AHb08VR9HP

OUTES AHb08VR9HP
Image: OUTESrequest removal

The OUTES AHb08VR9HP is an air-to-water heat pump with a SCOP of 4.98 (35 °C) and a sound power level of 60 dB(A).1,2,3

Key figures

SCOP (35 °C)
4.983

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Outdoor unit sound power
60dB(A)3
Official source
Refrigerant
R2901
Official source
Type (source)
Air-to-water1
Official source
Rated output 35 °C
7kW3
Official source
MT

Rules in Malta

Water Heater Scheme (heat pump water heaters)

Unknown

REWS runs a national grant scheme for energy-efficient water heaters in homes; heat pump water heaters are eligible (alongside solar water heaters). The scheme has been extended to 31 December 2026, and part A of the application must be submitted before you buy and install the equipment. Grant amounts: see the REWS page (not verified by us).

Technical specifications

General
Type (source)Air-to-water1
Compressors11
Capacity controldrehzahlregelung1
Performance
Rated output 35 °C7 kW3
Rated output 55 °C7 kW3
Efficiency
SCOP (35 °C)4.983
SCOP (55 °C)3.83
Seasonal efficiency ηs 35 °C196 %3
Seasonal efficiency ηs 55 °C149 %3
Energy label 35 °CA+++3
Energy label 55 °CA++3
COP A7/W3551
COP A2/W354.751
COP A-7/W353.011
Noise
Outdoor unit sound power60 dB(A)3
Refrigerant
RefrigerantR2901
Refrigerant GWP32
Refrigerant charge0.9 kg1
Electrical
Max. power input3.5 kW1
Connectivity & smart
SG ReadyYes1
Grants & market
ISDE grant (NL)2,575 €2

How it ranks

SCOP (35 °C): better than 78% of comparable models in our database (Heat pumps · Air-to-water · 6–8 kW; n = 175).

Rank 36 of 176

Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.

Manufacturer documentation

External links to OUTES's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.

Compare with

Similar models

Other brands, same type and a comparable size.

More from OUTES

All OUTES models (9) →

How we collect and check this data →

Frequently asked questions

Which refrigerant does the OUTES AHb08VR9HP use?

The OUTES AHb08VR9HP uses R290.1,2,3

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 28 Sept 2026
  3. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026
  4. Water Heater Scheme (heat pump water heaters) — Regulator for Energy and Water Services (REWS)