NIBE S1157-13 EM 1X230V
The NIBE S1157-13 EM 1X230V is a heat pump with SCOP (35 °C) 5.43 and refrigerant R290.1,2
Key figures
Rules in Malta
Water Heater Scheme (heat pump water heaters)
UnknownREWS runs a national grant scheme for energy-efficient water heaters in homes; heat pump water heaters are eligible (alongside solar water heaters). The scheme has been extended to 31 December 2026, and part A of the application must be submitted before you buy and install the equipment. Grant amounts: see the REWS page (not verified by us).
Technical specifications
| General | |
|---|---|
| Type (source) | Ground source1 |
| Performance | |
| Rated output 35 °C | 12 kW2 |
| Rated output 55 °C | 12 kW2 |
| Efficiency | |
| SCOP (35 °C) | 5.432 |
| SCOP (55 °C) | 4.12 |
| Seasonal efficiency ηs 35 °C | 214 %2 |
| Seasonal efficiency ηs 55 °C | 161 %2 |
| Energy label 35 °C | A+++2 |
| Energy label 55 °C | A+++2 |
| Noise | |
| Indoor unit sound power | 43 dB(A)2 |
| Refrigerant | |
| Refrigerant | R2901 |
| Refrigerant GWP | 31 |
| Refrigerant charge | 0.54 kg1 |
How it ranks
SCOP (35 °C): better than 69% of comparable models in our database (Heat pumps · Ground source · 10–14 kW; n = 46).
Rank 15 of 47
Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.
Variants
This model is registered in 17 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:
- S1157-13 EM 1X230V
- S1157-13 EM 3X230V
- S1157-13 EM 3X400V
- S1157-13 PC EM 1X230V
- S1157-13 PC EM 3X400V
- S1157-13 T EM 3X400V
- S1257-13 CU EM 3X400V
- S1257-13 CU PC EM 3X400V
- S1257-13 E EM 3X400V
- S1257-13 E PC EM 3X400V
- S1257-13 E T EM 3X400V
- S1257-13 R EM 1X230V
- S1257-13 R EM 1X230V UK
- S1257-13 R EM 3X230V
- S1257-13 R EM 3X400V
- S1257-13 R PC EM 1X230V
- S1257-13 R PC EM 3X400V
Similar models
Other brands, same type and a comparable size.
More from NIBE
- NIBE F1145-10 1x230 SCOP (35 °C): 4.9
- NIBE F1145-10 3x400 SCOP (35 °C): 5.05
- NIBE F2120-20 SCOP (35 °C): 5.05
- NIBE S2125-20 3X400V SCOP (35 °C): 5.3
- NIBE S2125-14 SCOP (35 °C): 5.27
- NIBE F1145-12 1x230 SCOP (35 °C): 4.58
How we collect and check this data →
Frequently asked questions
Sources
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 18 Oct 2026
- European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026
- Water Heater Scheme (heat pump water heaters) — Regulator for Energy and Water Services (REWS)