Heat pumps · MT

ClimerACP12T

The Climer ACP12T is an air-to-water heat pump with a SCOP of 4.47 (35 °C) and a sound power level of 62 dB(A).1,2

Last updated: Technical specifications ⇄ Compare this model

Key figures

SCOP (35 °C)
4.472

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Heating capacity (A7/W35)
11.8kW2
Official source
Outdoor unit sound power
62dB(A)2
Official source
Refrigerant
R322
Official source
Type (source)
Air-to-water2
Official source

Technical specifications

General
Type (source) Air-to-water2
Performance
Heating capacity (A7/W35) 11.8 kW2
Rated output 35 °C 10 kW2
Rated output 55 °C 10 kW2
Efficiency
SCOP (35 °C) 4.472
SCOP (55 °C) 3.362
Seasonal efficiency ηs 35 °C 176 %2
Seasonal efficiency ηs 55 °C 131 %2
Energy label 35 °C A, , , 2
Energy label 55 °C A, , 2
COP A7/W35 4.322
SEER (cooling) 4.432
Noise
Outdoor unit sound power 62 dB(A)2
Refrigerant
Refrigerant R322
Refrigerant GWP 6752
Refrigerant charge 2.5 kg2
Grants & market
ISDE grant (NL) 3,250 €1

Variants

This model is registered in 2 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:

  • ACP12T
  • ACP12

Frequently asked questions

Which refrigerant does the Climer ACP12T use?

The Climer ACP12T uses R32.1,2

Sources

  1. ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 27 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026