Novelan SICV 16.2(H)(K)3

The Novelan SICV 16.2(H)(K)3 is a heat pump with SCOP (35 °C) 5.17 and refrigerant R407C.1
Key figures
Rules in Malta
Water Heater Scheme (heat pump water heaters)
UnknownREWS runs a national grant scheme for energy-efficient water heaters in homes; heat pump water heaters are eligible (alongside solar water heaters). The scheme has been extended to 31 December 2026, and part A of the application must be submitted before you buy and install the equipment. Grant amounts: see the REWS page (not verified by us).
Technical specifications
| General | |
|---|---|
| Type (source) | Ground source1 |
| Performance | |
| Rated output 35 °C | 15.9 kW1 |
| Rated output 55 °C | 16 kW1 |
| Efficiency | |
| SCOP (35 °C) | 5.171 |
| SCOP (55 °C) | 4.051 |
| Seasonal efficiency ηs 35 °C | 199 %1 |
| Seasonal efficiency ηs 55 °C | 154 %1 |
| Energy label 35 °C | A+++1 |
| Energy label 55 °C | A+++1 |
| Noise | |
| Indoor unit sound power | 44 dB(A)1 |
| Refrigerant | |
| Refrigerant | R407C1 |
| Refrigerant GWP | 1,7741 |
| Refrigerant charge | 2.2 kg1 |
How it ranks
SCOP (35 °C): better than 52% of comparable models in our database (Heat pumps · Ground source · ≥ 14 kW; n = 123).
Rank 60 of 124
Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.
Variants
This model is registered in 4 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:
- SICV 16.2(H)(K)3
- alpha innotec PWZSV 162H3S
- alpha innotec SWCV 162(H)(K)3
- alpha innotec WZSV 162(H)(K)3M
Manufacturer documentation
- Product page
- Manual — Sole/Wasser-Wärmepumpen SICV – Bedienungsanleitung (400 V)
External links to Novelan's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.
Similar models
Other brands, same type and a comparable size.
More from Novelan
- Novelan SI 14.2H3 SCOP (35 °C): 5.55
- Novelan Helox SE 14 1P SCOP (35 °C): 5.15
- Novelan SI 17.2H3 SCOP (35 °C): 5.35
- Novelan SI 19.2H3 SCOP (35 °C): 5.33
- Novelan SICV 12.2(H)(K)3 SCOP (35 °C): 5.22
- Novelan SI 23.2H3 SCOP (35 °C): 5.35
How we collect and check this data →
Frequently asked questions
Sources
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- Water Heater Scheme (heat pump water heaters) — Regulator for Energy and Water Services (REWS)