Heat pumps · Compare

Midea MHC-V18WD2RN7 vs TEMPLARI Unità esterna KITA-LP-22, 3Ph, vers. MONOBLOCCO R-290

SCOP (35 °C): Midea MHC-V18WD2RN7 4.75, TEMPLARI Unità esterna KITA-LP-22, 3Ph, vers. MONOBLOCCO R-290 5.17. The TEMPLARI Unità esterna KITA-LP-22, 3Ph, vers. MONOBLOCCO R-290 is better on 8 of 15 comparable points.

Who wins where

  • Midea MHC-V18WD2RN7
  • TEMPLARI Unità esterna KITA-LP-22, 3Ph, vers. MONOBLOCCO R-290
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: Midea MHC-V18WD2RN7 83, TEMPLARI Unità esterna KITA-LP-22, 3Ph, vers. MONOBLOCCO R-290 83; Efficiency: Midea MHC-V18WD2RN7 44, TEMPLARI Unità esterna KITA-LP-22, 3Ph, vers. MONOBLOCCO R-290 59; Noise: Midea MHC-V18WD2RN7 16, TEMPLARI Unità esterna KITA-LP-22, 3Ph, vers. MONOBLOCCO R-290 20; Refrigerant: Midea MHC-V18WD2RN7 60, TEMPLARI Unità esterna KITA-LP-22, 3Ph, vers. MONOBLOCCO R-290 46; Connectivity & smart: Midea MHC-V18WD2RN7 50, TEMPLARI Unità esterna KITA-LP-22, 3Ph, vers. MONOBLOCCO R-290 50

Biggest differences

FactMHC-V18WD2RN7Unità esterna KITA-LP-22, 3Ph, vers. MONOBLOCCO R-290
Refrigerant charge1.8 kg3.4 kg
Heating capacity (A7/W35)18 kW22 kW
COP A-7/W352.83.08
Seasonal efficiency ηs 35 °C187 %204 %
SCOP (35 °C)4.755.17
COP A2/W354.444.09
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specifications MideaMHC-V18WD2RN7 TEMPLARIUnità esterna KITA-LP-22, 3Ph, vers. MONOBLOCCO R-290
Grants & market
SEAI Heat Pump System Grant €14,500€14,500
General
Type (source) Air-to-water 1 Air-to-water 1
Performance
Heating capacity (A7/W35) 18 kW 2 22 kW ✓ 3
Rated output 35 °C 18 kW 1 18.32 kW ✓ 1
Rated output 55 °C 18 kW ✓ 1 17.1 kW 1
Min. outdoor temperature -22 °C 2 -22 °C 3
Efficiency
SCOP (35 °C) 4.75 1 5.17 ✓ 1
SCOP (55 °C) 3.78 1 3.95 ✓ 1
Seasonal efficiency ηs 35 °C 187 % 1 204 % ✓ 1
Seasonal efficiency ηs 55 °C 148 % 1 155 % ✓ 1
Energy label 35 °C A, , , 2 A, , , 3
Energy label 55 °C A, , 2 A, , , 3
COP A7/W35 4.6 ✓ 1 4.52 1
COP A2/W35 4.44 ✓ 1 4.09 1
COP A-7/W35 2.8 1 3.08 ✓ 1
Noise
Outdoor unit sound power 64 dB(A) 1 62 dB(A) ✓ 1
Refrigerant
Refrigerant R290 1 R290 1
Refrigerant GWP 3 2 3 3
Refrigerant charge 1.8 kg ✓ 1 3.4 kg 1
Electrical
Max. power input 8.78 kW 1 6.51 kW 1
Connectivity & smart
SG Ready Yes 1 Yes 1

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026