Inventor ATS14T/HU160T9 vs Remeha Confida MB 400-14

SCOP (35 °C): Inventor ATS14T/HU160T9 4.72, Remeha Confida MB 400-14 4.7. Both models win equally often (7 of 15 points).
Last updated: + Add a model
Both models in detail
Who wins where
- Inventor ATS14T/HU160T9
- Remeha Confida MB 400-14
Biggest differences
| Fact | ATS14T/HU160T9 | Confida MB 400-14 |
|---|---|---|
| Refrigerant GWP | 675 | 3 |
| Refrigerant charge | 1.84 kg | 1.25 kg |
| Indoor unit sound power | 43 dB(A) | 30 dB(A) |
| Outdoor unit sound power | 65 dB(A) | 52 dB(A) |
| Rated output 55 °C | 12.08 kW | 13.7 kW |
| Seasonal efficiency ηs 55 °C | 136 % | 146.2 % |
Score per area = position (0–100) relative to all 1350 models in this category; higher is better.
| Technical specifications | InventorATS14T/HU160T9 | RemehaConfida MB 400-14 |
|---|---|---|
| Grants & market | ||
| SEAI Heat Pump System Grant | €14,500 | €14,500 |
| General | ||
| Type (source) | Air-to-water1 | Air-to-water1 |
| Performance | ||
| Heating capacity (A7/W35) | 14.5 kW✓2 | 13.5 kW3 |
| Rated output 35 °C | 13.73 kW✓1 | 13.7 kW1 |
| Rated output 55 °C | 12.08 kW1 | 13.7 kW✓1 |
| Min. outdoor temperature | -22 °C2 | – |
| Efficiency | ||
| SCOP (35 °C) | 4.72✓1 | 4.71 |
| SCOP (55 °C) | 3.481 | 3.73✓1 |
| Seasonal efficiency ηs 35 °C | 186 %✓1 | 184.9 %1 |
| Seasonal efficiency ηs 55 °C | 136 %1 | 146.2 %✓1 |
| Energy label 35 °C | A+++2 | A+++3 |
| Energy label 55 °C | A++2 | A++3 |
| COP A7/W35 | 4.7✓1 | 4.61 |
| COP A2/W35 | 4.52✓1 | 4.461 |
| COP A-7/W35 | 2.79✓1 | 2.71 |
| Noise | ||
| Outdoor unit sound power | 65 dB(A)1 | 52 dB(A)✓1 |
| Indoor unit sound power | 43 dB(A)1 | 30 dB(A)✓1 |
| Refrigerant | ||
| Refrigerant | R321 | R2901 |
| Refrigerant GWP | 6752 | 3✓3 |
| Refrigerant charge | 1.84 kg1 | 1.25 kg✓1 |
| Electrical | ||
| Max. power input | 3.15 kW1 | 6.4 kW1 |
| Connectivity & smart | ||
| SG Ready | Yes1 | Yes1 |
Frequently asked questions
Which is better: the Inventor ATS14T/HU160T9 or the Remeha Confida MB 400-14?
SCOP (35 °C): Inventor ATS14T/HU160T9 4.72, Remeha Confida MB 400-14 4.7. Both models win equally often (7 of 15 points).
What is the SCOP (35 °C) of the Inventor ATS14T/HU160T9 and the Remeha Confida MB 400-14?
Inventor ATS14T/HU160T9: 4.72. Remeha Confida MB 400-14: 4.7.
Which is better on refrigerant GWP: the Inventor ATS14T/HU160T9 or the Remeha Confida MB 400-14?
Remeha Confida MB 400-14: 3. Inventor ATS14T/HU160T9: 675.
Which is better on refrigerant charge: the Inventor ATS14T/HU160T9 or the Remeha Confida MB 400-14?
Remeha Confida MB 400-14: 1.25 kg. Inventor ATS14T/HU160T9: 1.84 kg.
Related comparisons
- InventorATS14T/HU160T9vsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.16-230-V001
- InventorATS14T/HU160T9vsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.16-400-V001
- InventorATS14T/HU160T9vsViessmannVitocal 250-A IDU-A AWMIW.A1.19-V052 ODU 250-A AWMOF-251.A1.16-400-V001
- InventorATS14T/HU160T9vsViessmannVitocal 250-A IDU-A AWMIW.A1.19-V052 ODU 250-A AWMOF-251.A1.19-400-V001
- InventorATS14T/HU160T9vsViessmannVitocal 250-A IDU-A AWMIW.A1.19-V052 ODU 250-A AWMOF-251.A1.16-400-V002
- InventorATS14T/HU160T9vsMideaMHC-V14WD2RN7
How we collect and check this data →
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 28 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026