Heat pumps · IE

Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.06-230-V002 (Keymark 45936)

Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.06-230-V002 (Keymark 45936)
Image: Viessmannrequest removal

The Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.06-230-V002 (Keymark 45936) is an air-to-water heat pump with a SCOP of 4.71 (35 °C) and a sound power level of 47 dB(A). In Ireland a heat pump is exempt from planning permission if it stays below 43 dB(A) (or 5 dB(A) above background noise, if higher), measured at the nearest neighbouring inhabited dwelling. Free-standing, the indicative minimum distance is 0.6 m; against a wall 0.9 m.1

Key figures

SCOP (35 °C)
4.711

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Heating capacity (A7/W35)
4.8kW1
Official source
Outdoor unit sound power
47dB(A)1
Official source
Refrigerant
R2901
Official source
Type (source)
Air-to-water1
Official source
IE

Rules in Ireland

Minimum distance to your neighbour

Planning and Development (Exempted Development) Regulations 2026 (S.I. No. 342 of 2026)2 · nearest neighbouring inhabited dwelling

Planning exemption: max 43 dB(A), or 5 dB(A) above background noise if higher≤ 43 dB(A) · normal operation
Free-standing0.6 m
Against wall0.9 m
In corner1.3 m

Indicative calculation (hemispherical, no barriers). Your installer must confirm the noise level at the nearest neighbouring dwelling.

SEAI Heat Pump System Grant

Not eligible

Up to €14,500 for a house (€11,500 for an apartment), including a €2,000 boiler scrappage grant when an oil, gas, solid-fuel or storage-heater system is removed. Homes built before 2007 need a technical assessment (€200 grant) unless the BER shows a Heat Loss Indicator of 2.3 or less. Installation is charged at 9% VAT.4

  • The heat pump must be listed on SEAI's Home Appliance Register of Performance (HARP) and installed by an SEAI-registered contractor.
  • Home built and occupied before 2021, with an MPRN; grant approval before any work starts and a BER assessment afterwards.
  • Hybrid heat pumps (with a gas or oil boiler) are not covered by the SEAI heat pump grant.

Heat pumps: grants and rules in Ireland →

Technical specifications

General
Type (source)Air-to-water1
SystemHybrid (with gas boiler)1
Performance
Heating capacity (A7/W35)4.8 kW1
Rated output 35 °C5.41 kW1
Rated output 55 °C5.11 kW1
Min. outdoor temperature-20 °C1
Efficiency
SCOP (35 °C)4.711
SCOP (55 °C)3.651
Seasonal efficiency ηs 35 °C183 %1
Seasonal efficiency ηs 55 °C141 %1
Energy label 35 °CA+++1
Energy label 55 °CA++1
COP A7/W355.11
Noise
Outdoor unit sound power47 dB(A)1
Indoor unit sound power40 dB(A)1
Refrigerant
RefrigerantR2901
Refrigerant GWP31
Refrigerant charge1.2 kg1

How it ranks

SCOP (35 °C): better than 50% of comparable models in our database (Heat pumps · Air-to-water · 4–6 kW; n = 114).

Rank 55 of 115

Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.

Manufacturer documentation

External links to Viessmann's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.

Similar models

Other brands, same type and a comparable size.

More from Viessmann

All Viessmann models (70) →

Featured in these lists

How we collect and check this data →

Frequently asked questions

Do I need planning permission for the Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.06-230-V002 (Keymark 45936) in Ireland?

Not if it meets the exempted-development conditions (Planning and Development (Exempted Development) Regulations 2026 (S.I. No. 342 of 2026)): no more than 43 dB(A) at the nearest neighbouring inhabited dwelling, or 5 dB(A) above background noise if that is higher. With a sound power of 47 dB(A) that indicatively means 0.6 m free-standing, 0.9 m against a wall or 1.3 m in a corner. Ask your SEAI-registered installer to confirm.1

Which refrigerant does the Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.06-230-V002 (Keymark 45936) use?

The Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.06-230-V002 (Keymark 45936) uses R290.1

Sources

  1. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  2. Planning and Development (Exempted Development) Regulations 2026 (S.I. No. 342 of 2026)
  3. Heat Pump System Grants — SEAI · accessed 4 Oct 2026
  4. Heat pump heating system (VAT) — Revenue · accessed 4 Oct 2026