Heat pumps · IE

Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.04-230-V002

Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.04-230-V002
Image: Viessmannrequest removal

The Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.04-230-V002 is an air-to-water heat pump with a SCOP of 4.57 (35 °C) and a sound power level of 46 dB(A). In Ireland a heat pump is exempt from planning permission if it stays below 43 dB(A) (or 5 dB(A) above background noise, if higher), measured at the nearest neighbouring inhabited dwelling. Free-standing, the indicative minimum distance is 0.6 m; against a wall 0.8 m.1,2

Key figures

SCOP (35 °C)
4.571

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Heating capacity (A7/W35)
4kW2
Official source
Outdoor unit sound power
46dB(A)1
Official source
Refrigerant
R2901
Official source
Type (source)
Air-to-water1
Official source
IE

Rules in Ireland

Minimum distance to your neighbour

Planning and Development (Exempted Development) Regulations 2026 (S.I. No. 342 of 2026)3 · nearest neighbouring inhabited dwelling

Planning exemption: max 43 dB(A), or 5 dB(A) above background noise if higher≤ 43 dB(A) · normal operation
Free-standing0.6 m
Against wall0.8 m
In corner1.1 m

Indicative calculation (hemispherical, no barriers). Your installer must confirm the noise level at the nearest neighbouring dwelling.

SEAI Heat Pump System Grant

Not eligible

Up to €14,500 for a house (€11,500 for an apartment), including a €2,000 boiler scrappage grant when an oil, gas, solid-fuel or storage-heater system is removed. Homes built before 2007 need a technical assessment (€200 grant) unless the BER shows a Heat Loss Indicator of 2.3 or less. Installation is charged at 9% VAT.5

  • The heat pump must be listed on SEAI's Home Appliance Register of Performance (HARP) and installed by an SEAI-registered contractor.
  • Home built and occupied before 2021, with an MPRN; grant approval before any work starts and a BER assessment afterwards.
  • Hybrid heat pumps (with a gas or oil boiler) are not covered by the SEAI heat pump grant.

Heat pumps: grants and rules in Ireland →

Technical specifications

General
Type (source)Air-to-water1
SystemHybrid (with gas boiler)1
Compressors11
Capacity controlInverter1
Performance
Heating capacity (A7/W35)4 kW2
Rated output 35 °C4.08 kW1
Rated output 55 °C3.77 kW1
Min. outdoor temperature-20 °C2
Efficiency
SCOP (35 °C)4.571
SCOP (55 °C)3.331
Seasonal efficiency ηs 35 °C180 %1
Seasonal efficiency ηs 55 °C130 %1
Energy label 35 °CA+++2
Energy label 55 °CA++2
COP A7/W355.731
COP A2/W354.421
COP A-7/W353.181
Noise
Outdoor unit sound power46 dB(A)1
Indoor unit sound power40 dB(A)1
Refrigerant
RefrigerantR2901
Refrigerant GWP32
Refrigerant charge1.2 kg1
Electrical
Max. power input0.78 kW1
Connectivity & smart
SG ReadyYes1

How it ranks

SCOP (35 °C): better than 28% of comparable models in our database (Heat pumps · Air-to-water · 4–6 kW; n = 114).

Rank 82 of 115

Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.

Variants

This model is registered in 3 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:

  • Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.04-230-V002
  • IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.04-230-V002
  • IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.04-230-V002

Manufacturer documentation

External links to Viessmann's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.

Similar models

Other brands, same type and a comparable size.

More from Viessmann

All Viessmann models (70) →

Featured in these lists

How we collect and check this data →

Frequently asked questions

Do I need planning permission for the Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.04-230-V002 in Ireland?

Not if it meets the exempted-development conditions (Planning and Development (Exempted Development) Regulations 2026 (S.I. No. 342 of 2026)): no more than 43 dB(A) at the nearest neighbouring inhabited dwelling, or 5 dB(A) above background noise if that is higher. With a sound power of 46 dB(A) that indicatively means 0.6 m free-standing, 0.8 m against a wall or 1.1 m in a corner. Ask your SEAI-registered installer to confirm.1,2

Which refrigerant does the Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.04-230-V002 use?

The Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.04-230-V002 uses R290.1,2

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Planning and Development (Exempted Development) Regulations 2026 (S.I. No. 342 of 2026)
  4. Heat Pump System Grants — SEAI · accessed 4 Oct 2026
  5. Heat pump heating system (VAT) — Revenue · accessed 4 Oct 2026