Heat pumps · IE

Metro Therm Metro delta PA-P-PVT

Metro Therm Metro delta PA-P-PVT
Image: Metro Thermrequest removal

The Metro Therm Metro delta PA-P-PVT is a heat pump with SCOP (35 °C) 6.03 and refrigerant R290 (PROPAAN).1,2

Key figures

SCOP (35 °C)
6.032

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Refrigerant
R2901PROPAAN
Official source
Type (source)
Water-to-water1
Official source
Rated output 35 °C
4kW2
Official source
Rated output 55 °C
4kW2
Official source
IE

Rules in Ireland

SEAI Heat Pump System Grant

Check conditions

€14,5003Maximum for a house, incl. €2,000 boiler scrappage

Up to €14,500 for a house (€11,500 for an apartment), including a €2,000 boiler scrappage grant when an oil, gas, solid-fuel or storage-heater system is removed. Homes built before 2007 need a technical assessment (€200 grant) unless the BER shows a Heat Loss Indicator of 2.3 or less. Installation is charged at 9% VAT.4

  • The heat pump must be listed on SEAI's Home Appliance Register of Performance (HARP) and installed by an SEAI-registered contractor.
  • Home built and occupied before 2021, with an MPRN; grant approval before any work starts and a BER assessment afterwards.

Heat pumps: grants and rules in Ireland →

Technical specifications

General
Type (source)Water-to-water1
Performance
Rated output 35 °C4 kW2
Rated output 55 °C4 kW2
Efficiency
SCOP (35 °C)6.032
SCOP (55 °C)4.582
Seasonal efficiency ηs 35 °C238 %2
Seasonal efficiency ηs 55 °C180 %2
Energy label 35 °CA+++2
Energy label 55 °CA+++2
Noise
Indoor unit sound power43 dB(A)2
Refrigerant
RefrigerantR290 (PROPAAN)1
Refrigerant GWP31
Grants & market
ISDE grant (NL)4,425 €1

Manufacturer documentation

External links to Metro Therm's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.

How we collect and check this data →

Frequently asked questions

What is the SCOP (35 °C) of the Metro Therm Metro delta PA-P-PVT?

The SCOP (35 °C) of the Metro Therm Metro delta PA-P-PVT is 6.03.1,2

Which refrigerant does the Metro Therm Metro delta PA-P-PVT use?

The refrigerant of the Metro Therm Metro delta PA-P-PVT is R290 (PROPAAN).1,2

How much SEAI grant can you get for the Metro Therm Metro delta PA-P-PVT?

Up to €14,500 with the SEAI Heat Pump System Grant, including €2,000 boiler scrappage when an oil, gas, solid-fuel or storage-heater system is removed (€11,500 for an apartment). The home must be built and occupied before 2021, the heat pump must be on SEAI's HARP register and you need grant approval before work starts.1,2

Sources

  1. ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 25 Oct 2026
  2. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026
  3. Heat Pump System Grants — SEAI · accessed 4 Oct 2026
  4. Heat pump heating system (VAT) — Revenue · accessed 4 Oct 2026