Bosch Compress 5800i AW CS5800iAW 10 ORMB-T

The Bosch Compress 5800i AW CS5800iAW 10 ORMB-T is an air-to-water heat pump with a SCOP of 4.74 (35 °C) and a sound power level of 42 dB(A). In Ireland a heat pump is exempt from planning permission if it stays below 43 dB(A) (or 5 dB(A) above background noise, if higher), measured at the nearest neighbouring inhabited dwelling. Free-standing, the indicative minimum distance is 0.5 m; against a wall 0.5 m.1
Key figures
Rules in Ireland
Minimum distance to your neighbour
Planning and Development (Exempted Development) Regulations 2026 (S.I. No. 342 of 2026)2 · nearest neighbouring inhabited dwelling
Indicative calculation (hemispherical, no barriers). Your installer must confirm the noise level at the nearest neighbouring dwelling.
SEAI Heat Pump System Grant
Check conditions€14,5003Maximum for a house, incl. €2,000 boiler scrappage
Up to €14,500 for a house (€11,500 for an apartment), including a €2,000 boiler scrappage grant when an oil, gas, solid-fuel or storage-heater system is removed. Homes built before 2007 need a technical assessment (€200 grant) unless the BER shows a Heat Loss Indicator of 2.3 or less. Installation is charged at 9% VAT.4
- The heat pump must be listed on SEAI's Home Appliance Register of Performance (HARP) and installed by an SEAI-registered contractor.
- Home built and occupied before 2021, with an MPRN; grant approval before any work starts and a BER assessment afterwards.
Technical specifications
| General | |
|---|---|
| Type (source) | Air-to-water1 |
| Performance | |
| Heating capacity (A7/W35) | 5.57 kW1 |
| Rated output 35 °C | 10 kW1 |
| Rated output 55 °C | 10 kW1 |
| Min. outdoor temperature | -22 °C1 |
| Efficiency | |
| SCOP (35 °C) | 4.741 |
| SCOP (55 °C) | 3.611 |
| Seasonal efficiency ηs 35 °C | 186 %1 |
| Seasonal efficiency ηs 55 °C | 141 %1 |
| Energy label 35 °C | A+++1 |
| Energy label 55 °C | A++1 |
| COP A7/W35 | 4.811 |
| Noise | |
| Outdoor unit sound power | 42 dB(A)1 |
| Indoor unit sound power | 37 dB(A)1 |
| Refrigerant | |
| Refrigerant | R2901 |
| Refrigerant GWP | 31 |
| Refrigerant charge | 1.7 kg1 |
How it ranks
SCOP (35 °C): better than 42% of comparable models in our database (Heat pumps · Air-to-water · 10–14 kW; n = 309).
Rank 174 of 310
Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.
Variants
This model is registered in 3 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:
- Compress 5800i AW CS5800iAW 10 ORMB-T
- CS5800iAW 10 ORMB-T (60°C)
- CS6800iAW 10 ORMB-T
Manufacturer documentation
- Product page
- Brochure / leaflet — Broschüre Bosch Wärmepumpe Compress 5800i AW / 6800i AW
- Manual — Bedienungsanleitung Luft-/Wasserwärmepumpe Compress 5800iAW | 6800iAW
- Manual — Installationsanleitung Inneneinheit Compress 5800i AW
External links to Bosch's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.
Similar models
Other brands, same type and a comparable size.
More from Bosch
- Bosch Compress 7000i AW CS7001i AW 13 O TH SCOP (35 °C): 4.92
- Bosch Compress 6800 AW 10 OR-T-Hybrid SCOP (35 °C): 4.41
- Bosch Compress CS3800iAW 10 OM-T (CS3800iAW O-T + AWMi) SCOP (35 °C): 5.01
- Bosch Compress CS5800iAW 10 ORE-T (AW 10 OR-T + CS5800iAW 12 E) SCOP (35 °C): 4.77
- Bosch Compress CS5800iAW 10 ORM-T (AW 10 OR-T + CS5800iAW 12 M) SCOP (35 °C): 4.73
- Bosch Compress CS6800iAW 10 ORE-T (AW 10 OR-T + CS6800iAW 12 E) SCOP (35 °C): 4.77
Featured in these lists
How we collect and check this data →
Frequently asked questions
Do I need planning permission for the Bosch Compress 5800i AW CS5800iAW 10 ORMB-T in Ireland?
Not if it meets the exempted-development conditions (Planning and Development (Exempted Development) Regulations 2026 (S.I. No. 342 of 2026)): no more than 43 dB(A) at the nearest neighbouring inhabited dwelling, or 5 dB(A) above background noise if that is higher. With a sound power of 42 dB(A) that indicatively means 0.5 m free-standing, 0.5 m against a wall or 0.7 m in a corner. Ask your SEAI-registered installer to confirm.1
How much SEAI grant can you get for the Bosch Compress 5800i AW CS5800iAW 10 ORMB-T?
Up to €14,500 with the SEAI Heat Pump System Grant, including €2,000 boiler scrappage when an oil, gas, solid-fuel or storage-heater system is removed (€11,500 for an apartment). The home must be built and occupied before 2021, the heat pump must be on SEAI's HARP register and you need grant approval before work starts.1
Which refrigerant does the Bosch Compress 5800i AW CS5800iAW 10 ORMB-T use?
The Bosch Compress 5800i AW CS5800iAW 10 ORMB-T uses R290.1
Sources
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- Planning and Development (Exempted Development) Regulations 2026 (S.I. No. 342 of 2026)
- Heat Pump System Grants — SEAI · accessed 4 Oct 2026
- Heat pump heating system (VAT) — Revenue · accessed 4 Oct 2026