Heat pumps · Compare

CLIVET EDGE Evo 2.0 + Mini / WiSAN-YME 1 S 4.1 + HQCN-NEE 1 MC A vs Görrissen Manufacturing EvoNova R11

SCOP (35 °C): CLIVET EDGE Evo 2.0 + Mini / WiSAN-YME 1 S 4.1 + HQCN-NEE 1 MC A 5.13, Görrissen Manufacturing EvoNova R11 4.92. The Görrissen Manufacturing EvoNova R11 is better on 8 of 13 comparable points.

Who wins where

  • CLIVET EDGE Evo 2.0 + Mini / WiSAN-YME 1 S 4.1 + HQCN-NEE 1 MC A
  • Görrissen Manufacturing EvoNova R11
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: CLIVET EDGE Evo 2.0 + Mini / WiSAN-YME 1 S 4.1 + HQCN-NEE 1 MC A 26, Görrissen Manufacturing EvoNova R11 35; Efficiency: CLIVET EDGE Evo 2.0 + Mini / WiSAN-YME 1 S 4.1 + HQCN-NEE 1 MC A 47, Görrissen Manufacturing EvoNova R11 73; Noise: CLIVET EDGE Evo 2.0 + Mini / WiSAN-YME 1 S 4.1 + HQCN-NEE 1 MC A 24, Görrissen Manufacturing EvoNova R11 35; Refrigerant: CLIVET EDGE Evo 2.0 + Mini / WiSAN-YME 1 S 4.1 + HQCN-NEE 1 MC A 49, Görrissen Manufacturing EvoNova R11 85; Connectivity & smart: CLIVET EDGE Evo 2.0 + Mini / WiSAN-YME 1 S 4.1 + HQCN-NEE 1 MC A 50, Görrissen Manufacturing EvoNova R11 50

Biggest differences

FactEDGE Evo 2.0 + Mini / WiSAN-YME 1 S 4.1 + HQCN-NEE 1 MC AEvoNova R11
Refrigerant charge1.4 kg0.9 kg
Rated output 55 °C6.6 kW8.3 kW
COP A2/W353.854.77
COP A7/W355.156.26
Seasonal efficiency ηs 55 °C131.5 %153.4 %
SCOP (55 °C)3.363.91
All specifications ↓

Score per area = position (0–100) relative to all 1000 models in this category; higher is better.

Technical specifications CLIVETEDGE Evo 2.0 + Mini / WiSAN-YME 1 S 4.1 + HQCN-NEE 1 MC A Görrissen ManufacturingEvoNova R11
Grants & market
Boiler Upgrade Scheme £7,500 – £9,000£7,500 – £9,000
Performance
Rated output 35 °C 8.1 kW 1 8.1 kW 1
Rated output 55 °C 6.6 kW 1 8.3 kW ✓ 1
Efficiency
SCOP (35 °C) 5.13 ✓ 1 4.92 1
SCOP (55 °C) 3.36 1 3.91 ✓ 1
Seasonal efficiency ηs 35 °C 205.6 % ✓ 1 193.8 % 1
Seasonal efficiency ηs 55 °C 131.5 % 1 153.4 % ✓ 1
COP A7/W35 5.15 1 6.26 ✓ 1
COP A2/W35 3.85 1 4.77 ✓ 1
COP A-7/W35 3 1 3.28 ✓ 1
Noise
Outdoor unit sound power 59 dB(A) 1 51 dB(A) ✓ 1
Indoor unit sound power 41 dB(A) ✓ 1 45 dB(A) 1
Refrigerant
Refrigerant R32 1 R290 1
Refrigerant charge 1.4 kg 1 0.9 kg ✓ 1
Electrical
Max. power input 3.4 kW 1 2.71 kW 1
Connectivity & smart
SG Ready Yes 1 Yes 1

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026