Daikin Airconditioning GermanyEWYK100QZXSA2

The Daikin Airconditioning Germany EWYK100QZXSA2 is an air-to-water heat pump with a SCOP of 4.29 (35 °C) and a sound power level of 77.7 dB(A). Under permitted development the limit is 42 dB(A) measured 1 m from the nearest neighbouring habitable-room window. Free-standing, the indicative minimum distance is 24.3 m; against a wall 34.4 m.

Last updated: Technical specifications Rules in the UK

Key figures

SCOP (35 °C)
4.29

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Outdoor unit sound power
77.7dB(A)
Official source
Refrigerant
R290
Official source
Rated output 35 °C
70kW
Official source
Rated output 55 °C
68.42kW
Official source
UK

Rules in the UK

These rules are still being verified.

Minimum distance to your neighbour

Permitted development rights + MCS 020 planning standard · 1 m from the nearest neighbouring habitable-room window

Permitted development (MCS 020) ≤ 42 dB(A) · at the assessment position
Free-standing 24.3 m
Against wall 34.4 m
In corner 48.6 m

Indicative calculation (hemispherical, no barriers). Not a substitute for an MCS 020 assessment. Source

Boiler Upgrade Scheme

Unknown

Fixed grant towards installation; check current amount with Ofgem. Ofgem

Technical specifications

General
Type Air-to-water BAFA
Compressors 2 BAFA
Capacity control Inverter BAFA
Performance
Rated output 35 °C 70 kW BAFA
Rated output 55 °C 68.42 kW BAFA
Efficiency
SCOP (35 °C) 4.29 BAFA
SCOP (55 °C) 3.38 BAFA
Seasonal efficiency ηs 35 °C 168.4 % BAFA
Seasonal efficiency ηs 55 °C 132.2 % BAFA
COP A7/W35 3.94 BAFA
COP A2/W35 3.55 BAFA
COP A-7/W35 2.86 BAFA
SEER (cooling) 5.06 BAFA
Noise
Outdoor unit sound power 77.7 dB(A) BAFA
Refrigerant
Refrigerant R290 BAFA
Refrigerant charge 6.08 kg BAFA
Electrical
Max. power input 30.42 kW BAFA
Connectivity & smart
SG Ready Yes BAFA

Frequently asked questions

Can I install the Daikin Airconditioning Germany EWYK100QZXSA2 without planning permission?

Under Permitted development rights + MCS 020 planning standard the unit must not exceed 42 dB(A) 1 m from the nearest neighbouring habitable-room window. With a sound power of 77.7 dB(A) that indicatively means 24.3 m free-standing, 34.4 m against a wall or 48.6 m in a corner. Your MCS installer must confirm this.

Which refrigerant does the Daikin Airconditioning Germany EWYK100QZXSA2 use?

The Daikin Airconditioning Germany EWYK100QZXSA2 uses R290.