Heat pumps · UK

Daikin Airconditioning GermanyDaikin Altherma 4 H W 8KW H/C

The Daikin Airconditioning Germany Daikin Altherma 4 H W 8KW H/C is an air-to-water heat pump with a SCOP of 5.14 (35 °C) and a sound power level of 45 dB(A). Under permitted development the limit is 42 dB(A) measured 1 m from the nearest neighbouring habitable-room window. Free-standing, the indicative minimum distance is 0.6 m; against a wall 0.8 m.

Last updated: Technical specifications Rules in the UK

Key figures

SCOP (35 °C)
5.14

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Outdoor unit sound power
45dB(A)
Official source
Refrigerant
R290
Official source
Rated output 35 °C
7.5kW
Official source
Rated output 55 °C
7.5kW
Official source
UK

Rules in the UK

These rules are still being verified.

Minimum distance to your neighbour

Permitted development rights + MCS 020 planning standard · 1 m from the nearest neighbouring habitable-room window

Permitted development (MCS 020) ≤ 42 dB(A) · at the assessment position
Free-standing 0.6 m
Against wall 0.8 m
In corner 1.1 m

Indicative calculation (hemispherical, no barriers). Not a substitute for an MCS 020 assessment. Source

Boiler Upgrade Scheme

Unknown

Fixed grant towards installation; check current amount with Ofgem. Ofgem

Technical specifications

General
Type Air-to-water BAFA
Compressors 1 BAFA
Capacity control Inverter BAFA
Performance
Rated output 35 °C 7.5 kW BAFA
Rated output 55 °C 7.5 kW BAFA
Efficiency
SCOP (35 °C) 5.14 BAFA
SCOP (55 °C) 3.95 BAFA
Seasonal efficiency ηs 35 °C 202 % BAFA
Seasonal efficiency ηs 55 °C 155 % BAFA
COP A7/W35 5.01 BAFA
COP A2/W35 4.46 BAFA
COP A-7/W35 3.32 BAFA
Noise
Outdoor unit sound power 45 dB(A) BAFA
Indoor unit sound power 45 dB(A) BAFA
Refrigerant
Refrigerant R290 BAFA
Refrigerant charge 1 kg BAFA
Electrical
Max. power input 4.32 kW BAFA
Connectivity & smart
SG Ready Yes BAFA

Frequently asked questions

Can I install the Daikin Airconditioning Germany Daikin Altherma 4 H W 8KW H/C without planning permission?

Under Permitted development rights + MCS 020 planning standard the unit must not exceed 42 dB(A) 1 m from the nearest neighbouring habitable-room window. With a sound power of 45 dB(A) that indicatively means 0.6 m free-standing, 0.8 m against a wall or 1.1 m in a corner. Your MCS installer must confirm this.

Which refrigerant does the Daikin Airconditioning Germany Daikin Altherma 4 H W 8KW H/C use?

The Daikin Airconditioning Germany Daikin Altherma 4 H W 8KW H/C uses R290.