The Bosch Home Comfort Cooling and Heating airH2O 600 S (5HP) RAS-5WHRP2E+RWM-5.0R3E is an air-to-water heat pump with a SCOP of 4.48 (35 °C) and a sound power level of 54 dB(A). Under permitted development the limit is 42 dB(A) measured 1 m from the nearest neighbouring habitable-room window. Free-standing, the indicative minimum distance is 1.6 m; against a wall 2.2 m.
Key figures
- SCOP (35 °C)
- 4.48
Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.
- Outdoor unit sound power
- 54dB(A)Official source
- Refrigerant
- R32Official source
- Rated output 35 °C
- 12kWOfficial source
- Rated output 55 °C
- 12kWOfficial source
Rules in the UK
These rules are still being verified.
Minimum distance to your neighbour
Permitted development rights + MCS 020 planning standard · 1 m from the nearest neighbouring habitable-room window
Indicative calculation (hemispherical, no barriers). Not a substitute for an MCS 020 assessment. Source
Boiler Upgrade Scheme
UnknownFixed grant towards installation; check current amount with Ofgem. Ofgem
Technical specifications
| General | ||
|---|---|---|
| Type | Air-to-water | BAFA |
| Compressors | 1 | BAFA |
| Capacity control | drehzahlregelung | BAFA |
| Performance | ||
| Rated output 35 °C | 12 kW | BAFA |
| Rated output 55 °C | 12 kW | BAFA |
| Efficiency | ||
| SCOP (35 °C) | 4.48 | BAFA |
| SCOP (55 °C) | 3.25 | BAFA |
| Seasonal efficiency ηs 35 °C | 176 % | BAFA |
| Seasonal efficiency ηs 55 °C | 127 % | BAFA |
| COP A7/W35 | 5.82 | BAFA |
| COP A2/W35 | 4.35 | BAFA |
| COP A-7/W35 | 2.91 | BAFA |
| Noise | ||
| Outdoor unit sound power | 54 dB(A) | BAFA |
| Indoor unit sound power | 41 dB(A) | BAFA |
| Refrigerant | ||
| Refrigerant | R32 | BAFA |
| Refrigerant charge | 2.1 kg | BAFA |
| Electrical | ||
| Max. power input | 9.12 kW | BAFA |
| Connectivity & smart | ||
| SG Ready | Yes | BAFA |
Frequently asked questions
Can I install the Bosch Home Comfort Cooling and Heating airH2O 600 S (5HP) RAS-5WHRP2E+RWM-5.0R3E without planning permission?
Under Permitted development rights + MCS 020 planning standard the unit must not exceed 42 dB(A) 1 m from the nearest neighbouring habitable-room window. With a sound power of 54 dB(A) that indicatively means 1.6 m free-standing, 2.2 m against a wall or 3.2 m in a corner. Your MCS installer must confirm this.
Which refrigerant does the Bosch Home Comfort Cooling and Heating airH2O 600 S (5HP) RAS-5WHRP2E+RWM-5.0R3E use?