Tecalor THZ 05.1 IB(C) comfort vs Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001
SCOP (35 °C): Tecalor THZ 05.1 IB(C) comfort 4,28, Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001 4,58. Model Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001 je boljši v 9 od 15 primerljivih točk.
Oba modela podrobno
Kje je kdo boljši
- Tecalor THZ 05.1 IB(C) comfort
- Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001
Največje razlike
| Merilo | THZ 05.1 IB(C) comfort | Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001 |
|---|---|---|
| Grelna moč (A7/W35) | 2,26 kW | 4,8 kW |
| Raven zvočne moči notranje enote | 53 dB(A) | 40 dB(A) |
| Raven zvočne moči zunanje enote | 44 dB(A) | 51 dB(A) |
| COP A2/W35 | 4,14 | 4,6 |
| Sezonska energijska učinkovitost ηs pri 55 °C | 128 % | 141 % |
| SCOP (55 °C) | 3,28 | 3,6 |
Ocena po merilu = položaj (0–100) glede na vse modele v tej kategoriji (skupaj 1350); višje je bolje.
| Tehnični podatki | TecalorTHZ 05.1 IB(C) comfort | ViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001 |
|---|---|---|
| Splošno | ||
| Tip (vir toplote) | Zrak-voda1 | Zrak-voda1 |
| Moč | ||
| Grelna moč (A7/W35) | 2,26 kW2 | 4,8 kW✓3 |
| Nazivna moč pri 35 °C | 5,47 kW✓1 | 5,46 kW1 |
| Nazivna moč pri 55 °C | 5,44 kW✓1 | 5,14 kW1 |
| Najnižja zunanja temperatura | – | −20 °C3 |
| Učinkovitost | ||
| SCOP (35 °C) | 4,281 | 4,58✓1 |
| SCOP (55 °C) | 3,281 | 3,6✓1 |
| Sezonska energijska učinkovitost ηs pri 35 °C | 168 %1 | 180 %✓1 |
| Sezonska energijska učinkovitost ηs pri 55 °C | 128 %1 | 141 %✓1 |
| Energijska nalepka pri 35 °C | A++2 | A+++3 |
| Energijska nalepka pri 55 °C | A++2 | A++3 |
| COP A7/W35 | 5,55✓1 | 5,51 |
| COP A2/W35 | 4,141 | 4,6✓1 |
| COP A-7/W35 | 2,91 | 3✓1 |
| Hrup | ||
| Raven zvočne moči zunanje enote | 44 dB(A)✓1 | 51 dB(A)1 |
| Raven zvočne moči notranje enote | 53 dB(A)1 | 40 dB(A)✓1 |
| Hladivo | ||
| Hladivo | R2901 | R2901 |
| GWP hladiva | 32 | 33 |
| Polnitev hladiva | 1,24 kg1 | 1,2 kg✓1 |
| Električni podatki | ||
| Največja priključna moč | 12,25 kW1 | 0,98 kW1 |
| Povezljivost in upravljanje | ||
| SG Ready | Da1 | Da1 |
Pogosta vprašanja
Kateri je boljši: Tecalor THZ 05.1 IB(C) comfort ali Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001?
SCOP (35 °C): Tecalor THZ 05.1 IB(C) comfort 4,28, Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001 4,58. Model Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001 je boljši v 9 od 15 primerljivih točk.
Kolikšna je vrednost SCOP (35 °C) pri Tecalor THZ 05.1 IB(C) comfort in Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001?
Tecalor THZ 05.1 IB(C) comfort: 4,28. Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001: 4,58.
Kateri je boljši pri grelna moč (A7/W35): Tecalor THZ 05.1 IB(C) comfort ali Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001?
Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001: 4,8 kW. Tecalor THZ 05.1 IB(C) comfort: 2,26 kW.
Kateri je boljši pri raven zvočne moči notranje enote: Tecalor THZ 05.1 IB(C) comfort ali Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001?
Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001: 40 dB(A). Tecalor THZ 05.1 IB(C) comfort: 53 dB(A).
Podobne primerjave
- ELCOAEROTOP SPK7vsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001
- STIEBEL ELTRONLWZ 05.1 Premium HKWL 230vsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001
- STIEBEL ELTRONLWZ 05.1 Plus H(K)WL 230vsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001
- ELCOAEROTOP SPK7vsViessmannVitocal 150-A IDU-A Hybrid HWMIW.A1.19-V054 / ODU 150-A AWMOF-151.A1.06-230-V002
- ViessmannVitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.06-230-V001vsWaterkotteEcoTouch Air Bloc 7006 (230V)
- ViessmannVitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 / ODU 250-A AWMOF-251.A1.06-230-V002vsWaterkotteEcoTouch Air Bloc 7006 (230V)
Kako zbiramo in preverjamo te podatke →
Viri
- Seznam upravičenih toplotnih črpalk (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · dostopano 27. sep. 2026
- Certifikati Heat Pump Keymark — EHPA / DIN CERTCO (Heat Pump KEYMARK) · dostopano 29. sep. 2026
- Certifikati Heat Pump Keymark — EHPA / DIN CERTCO (Heat Pump KEYMARK) · dostopano 29. sep. 2026