Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001 vs Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001

SCOP (35 °C): Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001 4.44, Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 4.44. The Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 is better on 4 of 16 comparable points.

Last updated: + Add a model

Both models in detail

Who wins where

  • Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001
  • Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001 22, Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 22; Efficiency: Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001 36, Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 39; Noise: Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001 65, Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 72; Refrigerant: Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001 74, Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 74; Connectivity & smart: Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001 50, Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 50

Biggest differences

FactVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001
Outdoor unit sound power51 dB(A)48 dB(A)
SCOP (55 °C)3.53.58
Seasonal efficiency ηs 55 °C137 %140 %
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specificationsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001ViessmannVitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001
General
Type (source)Air-to-water1Air-to-water1
Performance
Heating capacity (A7/W35)5.6 kW25.6 kW2
Rated output 35 °C6.47 kW16.47 kW1
Rated output 55 °C6.2 kW✓16.17 kW1
Min. outdoor temperature-20 °C2-20 °C2
Efficiency
SCOP (35 °C)4.4414.441
SCOP (55 °C)3.513.58✓1
Seasonal efficiency ηs 35 °C175 %1176 %✓1
Seasonal efficiency ηs 55 °C137 %1140 %✓1
Energy label 35 °CA+++2A+++2
Energy label 55 °CA++2A++2
COP A7/W356.216.21
COP A2/W354.214.21
COP A-7/W353131
Noise
Outdoor unit sound power51 dB(A)148 dB(A)✓1
Indoor unit sound power40 dB(A)140 dB(A)1
Refrigerant
RefrigerantR2901R2901
Refrigerant GWP3232
Refrigerant charge1.2 kg11.2 kg1
Electrical
Max. power input1.19 kW11.14 kW1
Connectivity & smart
SG ReadyYes1Yes1

Frequently asked questions

Which is better: the Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001 or the Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001?

SCOP (35 °C): Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001 4.44, Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 4.44. The Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 is better on 4 of 16 comparable points.

What is the SCOP (35 °C) of the Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001 and the Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001?

Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001: 4.44. Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001: 4.44.

Which is better on outdoor unit sound power: the Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001 or the Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001?

Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001: 48 dB(A). Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001: 51 dB(A).

Which is better on SCOP (55 °C): the Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001 or the Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001?

Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001: 3.58. Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001: 3.5.

How we collect and check this data →

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed Sep 27, 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed Sep 29, 2026