| Fact | EODU-V16-M1-AW-9E | THM16DFC |
|---|---|---|
| COP A7/W35 | 4.5 | 7.46 |
| Refrigerant charge | 1.5 kg | 1.35 kg |
| COP A-7/W35 | 2.45 | 2.7 |
| Heating capacity (A7/W35) | 15.5 kW | 16 kW |
| SCOP (35 °C) | 4.7 | 4.83 |
| Seasonal efficiency ηs 35 °C | 185 % | 190 % |
Score per area = position (0–100) relative to all 1350 models in this category; higher is better.
| Technical specifications | EnpalEODU-V16-M1-AW-9E | TCLTHM16DFC |
|---|---|---|
| General | ||
| Type (source) | Air-to-water1 | Air-to-water1 |
| Performance | ||
| Heating capacity (A7/W35) | 15.5 kW2 | 16 kW✓3 |
| Rated output 35 °C | 15.9 kW1 | 16 kW✓4 |
| Rated output 55 °C | 14.7 kW1 | 15 kW✓4 |
| Min. outdoor temperature | -22 °C2 | -22 °C3 |
| Efficiency | ||
| SCOP (35 °C) | 4.71 | 4.83✓4 |
| SCOP (55 °C) | 3.85✓1 | 3.834 |
| Seasonal efficiency ηs 35 °C | 185 %1 | 190 %✓4 |
| Seasonal efficiency ηs 55 °C | 151 %✓1 | 150 %4 |
| Energy label 35 °C | A+++2 | A+++4 |
| Energy label 55 °C | A+++2 | A+++4 |
| COP A7/W35 | 4.51 | 7.46✓1 |
| COP A2/W35 | – | 4.461 |
| COP A-7/W35 | 2.451 | 2.7✓1 |
| Noise | ||
| Outdoor unit sound power | 59 dB(A)1 | 59 dB(A)4 |
| Refrigerant | ||
| Refrigerant | R2901 | R2901 |
| Refrigerant GWP | 32 | 33 |
| Refrigerant charge | 1.5 kg1 | 1.35 kg✓1 |
| Electrical | ||
| Max. power input | 15.5 kW1 | 6.2 kW1 |
| Connectivity & smart | ||
| SG Ready | Yes1 | Yes1 |
| Grants & market | ||
| ISDE grant (NL) | – | 4,375 €5 |
Frequently asked questions
Which is better: the Enpal EODU-V16-M1-AW-9E or the TCL THM16DFC?
SCOP (35 °C): Enpal EODU-V16-M1-AW-9E 4.7, TCL THM16DFC 4.83. The TCL THM16DFC is better on 8 of 14 comparable points.
What is the SCOP (35 °C) of the Enpal EODU-V16-M1-AW-9E and the TCL THM16DFC?
Enpal EODU-V16-M1-AW-9E: 4.7. TCL THM16DFC: 4.83.
Which is better on COP A7/W35: the Enpal EODU-V16-M1-AW-9E or the TCL THM16DFC?
TCL THM16DFC: 7.46. Enpal EODU-V16-M1-AW-9E: 4.5.
Which is better on refrigerant charge: the Enpal EODU-V16-M1-AW-9E or the TCL THM16DFC?
TCL THM16DFC: 1.35 kg. Enpal EODU-V16-M1-AW-9E: 1.5 kg.
Related comparisons
How we collect and check this data →
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed Sep 27, 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed Sep 29, 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed Sep 29, 2026
- European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed Oct 15, 2026
- ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed Oct 25, 2026