Clivet WiSAN-PMP 1 S 12.1 vs AUX ACHM-H22/5R2A

SCOP (35 °C): Clivet WiSAN-PMP 1 S 12.1 4.95, AUX ACHM-H22/5R2A 5.2. The AUX ACHM-H22/5R2A is better on 10 of 14 comparable points.
Last updated: + Add a model
Both models in detail
Who wins where
- Clivet WiSAN-PMP 1 S 12.1
- AUX ACHM-H22/5R2A
Biggest differences
| Fact | WiSAN-PMP 1 S 12.1 | ACHM-H22/5R2A |
|---|---|---|
| COP A7/W35 | 4.77 | 6.93 |
| COP A2/W35 | 3.7 | 5.04 |
| Outdoor unit sound power | 68 dB(A) | 55 dB(A) |
| Heating capacity (A7/W35) | 25 kW | 22 kW |
| Seasonal efficiency ηs 55 °C | 151 % | 162 % |
| SCOP (55 °C) | 3.85 | 4.12 |
Score per area = position (0–100) relative to all 1350 models in this category; higher is better.
| Technical specifications | ClivetWiSAN-PMP 1 S 12.1 | AUXACHM-H22/5R2A |
|---|---|---|
| General | ||
| Type (source) | Air-to-water1 | Air-to-water1 |
| Performance | ||
| Heating capacity (A7/W35) | 25 kW✓2 | 22 kW3 |
| Rated output 35 °C | 25 kW4 | 26 kW✓1 |
| Rated output 55 °C | 25 kW4 | 26 kW✓1 |
| Min. outdoor temperature | -22 °C2 | – |
| Efficiency | ||
| SCOP (35 °C) | 4.954 | 5.2✓1 |
| SCOP (55 °C) | 3.854 | 4.12✓1 |
| Seasonal efficiency ηs 35 °C | 195 %4 | 205 %✓1 |
| Seasonal efficiency ηs 55 °C | 151 %4 | 162 %✓1 |
| Energy label 35 °C | A+++4 | A+++3 |
| Energy label 55 °C | A+++4 | A+++3 |
| COP A7/W35 | 4.771 | 6.93✓1 |
| COP A2/W35 | 3.71 | 5.04✓1 |
| COP A-7/W35 | 3.031 | 3.19✓1 |
| Noise | ||
| Outdoor unit sound power | 68 dB(A)4 | 55 dB(A)✓1 |
| Indoor unit sound power | 68 dB(A)1 | – |
| Refrigerant | ||
| Refrigerant | R2901 | R2901 |
| Refrigerant GWP | 32 | 33 |
| Refrigerant charge | 2.9 kg1 | 2.9 kg1 |
| Electrical | ||
| Max. power input | 14.5 kW1 | 21 kW1 |
| Connectivity & smart | ||
| SG Ready | Yes1 | Yes1 |
| Grants & market | ||
| ISDE grant (NL) | 6,400 €5 | – |
Frequently asked questions
Which is better: the Clivet WiSAN-PMP 1 S 12.1 or the AUX ACHM-H22/5R2A?
SCOP (35 °C): Clivet WiSAN-PMP 1 S 12.1 4.95, AUX ACHM-H22/5R2A 5.2. The AUX ACHM-H22/5R2A is better on 10 of 14 comparable points.
What is the SCOP (35 °C) of the Clivet WiSAN-PMP 1 S 12.1 and the AUX ACHM-H22/5R2A?
Clivet WiSAN-PMP 1 S 12.1: 4.95. AUX ACHM-H22/5R2A: 5.2.
Which is better on COP A7/W35: the Clivet WiSAN-PMP 1 S 12.1 or the AUX ACHM-H22/5R2A?
AUX ACHM-H22/5R2A: 6.93. Clivet WiSAN-PMP 1 S 12.1: 4.77.
Which is better on COP A2/W35: the Clivet WiSAN-PMP 1 S 12.1 or the AUX ACHM-H22/5R2A?
AUX ACHM-H22/5R2A: 5.04. Clivet WiSAN-PMP 1 S 12.1: 3.7.
Related comparisons
- ClivetWiSAN-PMP 1 S 12.1vsRemehaEffenca HT 30
- ClivetWiSAN-PMP 1 S 12.1vsTEMPLARIUnità esterna KITA-LP-32, 3Ph, vers. MONOBLOCCO R-290
- ClivetWiSAN-PMP 1 S 12.1vsTEMPLARIUNITÀ ESTERNA KITA-LP PLUS-35, 3PH, VERS. MONOBLOCCO R-290
- ClivetWiSAN-PMP 1 S 12.1vsTEMPLARIUnità esterna KITA-LP-35, 3Ph, vers. MONOBLOCCO R-290
- ClivetWiSAN-PMP 1 S 12.1vsPower WorldPW30-DKXLRE3-H8
- AUXACHM-H30/5R2AvsTEMPLARIUnità esterna KITA-LP-35, 3Ph, vers. MONOBLOCCO R-290
How we collect and check this data →
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed Sep 27, 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed Sep 29, 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed Sep 29, 2026
- European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed Oct 15, 2026
- ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed Sep 27, 2026