Heat pumps · INT

Tecalor TTL 13.1 AC comfort

Tecalor TTL 13.1 AC comfort
Image: Tecalorrequest removal

The Tecalor TTL 13.1 AC comfort is an air-to-water heat pump with a SCOP of 4.9 (35 °C) and a sound power level of 45 dB(A).1,2,3

Key figures

SCOP (35 °C)
4.93

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Heating capacity (A7/W35)
5.79kW2
Official source
Outdoor unit sound power
45dB(A)3
Official source
Refrigerant
R2901
Official source
Type (source)
Air-to-water1
Official source

Technical specifications

General
Type (source)Air-to-water1
Compressors11
Capacity controldrehzahlregelung1
Performance
Heating capacity (A7/W35)5.79 kW2
Rated output 35 °C15 kW3
Rated output 55 °C15 kW3
Min. outdoor temperature-22 °C2
Efficiency
SCOP (35 °C)4.93
SCOP (55 °C)43
Seasonal efficiency ηs 35 °C193 %3
Seasonal efficiency ηs 55 °C157 %3
Energy label 35 °CA+++3
Energy label 55 °CA+++3
COP A7/W355.411
COP A2/W354.411
COP A-7/W353.111
Noise
Outdoor unit sound power45 dB(A)3
Refrigerant
RefrigerantR2901
Refrigerant GWP32
Refrigerant charge2.15 kg1
Electrical
Max. power input8.61 kW1
Connectivity & smart
SG ReadyYes1

How it ranks

SCOP (35 °C): better than 68% of comparable models in our database (Heat pumps · Air-to-water · ≥ 14 kW; n = 219).

Rank 64 of 220

Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.

Variants

This model is registered in 2 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:

  • TTL 13.1 AC comfort
  • TTL 13.1 W AC comfort

Manufacturer documentation

External links to Tecalor's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.

Compare with

Similar models

Other brands, same type and a comparable size.

More from Tecalor

All Tecalor models (57) →

Featured in these lists

How we collect and check this data →

Frequently asked questions

Which refrigerant does the Tecalor TTL 13.1 AC comfort use?

The Tecalor TTL 13.1 AC comfort uses R290.1,2,3

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed Sep 27, 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed Sep 29, 2026
  3. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed Oct 15, 2026