Heat pumps · INT

Tecalor TTL 10.1 AC comfort

Tecalor TTL 10.1 AC comfort
Image: Tecalorrequest removal

The Tecalor TTL 10.1 AC comfort is an air-to-water heat pump with a SCOP of 4.95 (35 °C) and a sound power level of 46 dB(A).1,2,3

Key figures

SCOP (35 °C)
4.953

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Heating capacity (A7/W35)
4.32kW2
Official source
Outdoor unit sound power
46dB(A)3
Official source
Refrigerant
R2901
Official source
Type (source)
Air-to-water1
Official source

Technical specifications

General
Type (source)Air-to-water1
Compressors11
Capacity controldrehzahlregelung1
Performance
Heating capacity (A7/W35)4.32 kW2
Rated output 35 °C12 kW3
Rated output 55 °C12 kW3
Min. outdoor temperature-22 °C2
Efficiency
SCOP (35 °C)4.953
SCOP (55 °C)43
Seasonal efficiency ηs 35 °C195 %3
Seasonal efficiency ηs 55 °C157 %3
Energy label 35 °CA+++3
Energy label 55 °CA+++3
COP A7/W355.41
COP A2/W354.541
COP A-7/W353.151
Noise
Outdoor unit sound power46 dB(A)3
Refrigerant
RefrigerantR2901
Refrigerant GWP32
Refrigerant charge1.6 kg1
Electrical
Max. power input6.83 kW1
Connectivity & smart
SG ReadyYes1

How it ranks

SCOP (35 °C): better than 69% of comparable models in our database (Heat pumps · Air-to-water · 10–14 kW; n = 309).

Rank 93 of 310

Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.

Variants

This model is registered in 2 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:

  • TTL 10.1 AC comfort
  • TTL 10.1 W AC comfort

Manufacturer documentation

External links to Tecalor's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.

Compare with

Similar models

Other brands, same type and a comparable size.

More from Tecalor

All Tecalor models (57) →

Featured in these lists

How we collect and check this data →

Frequently asked questions

Which refrigerant does the Tecalor TTL 10.1 AC comfort use?

The Tecalor TTL 10.1 AC comfort uses R290.1,2,3

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed Sep 27, 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed Sep 29, 2026
  3. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed Nov 1, 2026