Heat pumps · INT

TCL THML-6D/HBp-A

TCL THML-6D/HBp-A
Image: TCLrequest removal

The TCL THML-6D/HBp-A is an air-to-water heat pump with a SCOP of 4.65 (35 °C) and a sound power level of 59 dB(A).1,2,3

Key figures

SCOP (35 °C)
4.653

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Heating capacity (A7/W35)
6.22kW2
Official source
Outdoor unit sound power
59dB(A)3
Official source
Refrigerant
R322
Official source
Type (source)
Air-to-water2
Official source

Technical specifications

General
Type (source)Air-to-water2
Performance
Heating capacity (A7/W35)6.22 kW2
Rated output 35 °C7 kW3
Rated output 55 °C6 kW3
Min. outdoor temperature-22 °C2
Efficiency
SCOP (35 °C)4.653
SCOP (55 °C)3.53
Seasonal efficiency ηs 35 °C183 %3
Seasonal efficiency ηs 55 °C137 %3
Energy label 35 °CA+++3
Energy label 55 °CA++3
COP A7/W354.92
Noise
Outdoor unit sound power59 dB(A)3
Refrigerant
RefrigerantR322
Refrigerant GWP6752
Refrigerant charge1.3 kg2
Grants & market
ISDE grant (NL)2,575 €1

How it ranks

SCOP (35 °C): better than 46% of comparable models in our database (Heat pumps · Air-to-water · 6–8 kW; n = 175).

Rank 93 of 176

Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.

Variants

This model is registered in 2 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:

  • THML-6D/HBp-A
  • THMLd-6D/3HBp-A

Manufacturer documentation

External links to TCL's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.

Compare with

Similar models

Other brands, same type and a comparable size.

More from TCL

All TCL models (30) →

How we collect and check this data →

Frequently asked questions

Which refrigerant does the TCL THML-6D/HBp-A use?

The TCL THML-6D/HBp-A uses R32.1,2,3

Sources

  1. ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed Sep 28, 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed Sep 29, 2026
  3. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed Oct 15, 2026