Heat pumps · INT

Fairland iGXC16T

The Fairland iGXC16T is an air-to-water heat pump with a SCOP of 5.18 (35 °C) and a sound power level of 54 dB(A).1,2,3

Last updated: Technical specifications⇄ Compare this model

Key figures

SCOP (35 °C)
5.181

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Heating capacity (A7/W35)
16.12kW3
Official source
Outdoor unit sound power
54dB(A)1
Official source
Refrigerant
R2901
Official source
Type (source)
Air-to-water1
Official source

Technical specifications

General
Type (source)Air-to-water1
Compressors11
Capacity controldrehzahlregelung1
Performance
Heating capacity (A7/W35)16.12 kW3
Rated output 35 °C15.63 kW1
Rated output 55 °C14.7 kW1
Efficiency
SCOP (35 °C)5.181
SCOP (55 °C)3.981
Seasonal efficiency ηs 35 °C204 %1
Seasonal efficiency ηs 55 °C156 %1
Energy label 35 °CA+++3
Energy label 55 °CA+++3
COP A7/W355.071
COP A2/W354.991
COP A-7/W353.021
Noise
Outdoor unit sound power54 dB(A)1
Refrigerant
RefrigerantR2901
Refrigerant GWP33
Refrigerant charge1.85 kg1
Electrical
Max. power input6.5 kW1
Connectivity & smart
SG ReadyYes1
Grants & market
ISDE grant (NL)4,375 €2

How it ranks

SCOP (35 °C): better than 85% of comparable models in our database (Heat pumps · Air-to-water · ≥ 14 kW; n = 219).

Rank 32 of 220

Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.

Variants

This model is registered in 2 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:

  • iGXC16T
  • iGXC16

Similar models

Other brands, same type and a comparable size.

More from Fairland

All Fairland models (4) →

How we collect and check this data →

Frequently asked questions

Which refrigerant does the Fairland iGXC16T use?

The Fairland iGXC16T uses R290.1,2,3

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed Nov 15, 2026
  2. ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed Oct 25, 2026
  3. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed Nov 1, 2026