Heat pumps · INT

ACOND Grandis-L21

The ACOND Grandis-L21 is an air-to-water heat pump with a SCOP of 4.95 (35 °C) and a sound power level of 53 dB(A).1,2

Last updated: Technical specifications⇄ Compare this model

Key figures

SCOP (35 °C)
4.951

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Heating capacity (A7/W35)
16.69kW2
Official source
Outdoor unit sound power
53dB(A)1
Official source
Refrigerant
R2901
Official source
Type (source)
Air-to-water1
Official source

Technical specifications

General
Type (source)Air-to-water1
Compressors11
Capacity controldrehzahlregelung1
Performance
Heating capacity (A7/W35)16.69 kW2
Rated output 35 °C21 kW1
Rated output 55 °C22 kW1
Efficiency
SCOP (35 °C)4.951
SCOP (55 °C)3.621
Seasonal efficiency ηs 35 °C195 %1
Seasonal efficiency ηs 55 °C142 %1
Energy label 35 °CA+++2
Energy label 55 °CA++2
COP A7/W357.591
COP A2/W354.61
COP A-7/W352.741
Noise
Outdoor unit sound power53 dB(A)1
Indoor unit sound power36 dB(A)1
Refrigerant
RefrigerantR2901
Refrigerant GWP32
Refrigerant charge2.6 kg1
Electrical
Max. power input14 kW1
Connectivity & smart
SG ReadyYes1

How it ranks

SCOP (35 °C): better than 76% of comparable models in our database (Heat pumps · Air-to-water · ≥ 14 kW; n = 219).

Rank 50 of 220

Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.

Variants

This model is registered in 2 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:

  • Grandis-L21
  • GRANDIS-L21

Compare with

Similar models

Other brands, same type and a comparable size.

More from ACOND

All ACOND models (4) →

How we collect and check this data →

Frequently asked questions

Which refrigerant does the ACOND Grandis-L21 use?

The ACOND Grandis-L21 uses R290.1,2

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed Sep 27, 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed Sep 29, 2026