REMKO WKM 170 vs RP Handels AI-290-19-400V
SCOP (35 °C): REMKO WKM 170 5.17, RP Handels AI-290-19-400V 4.66. The REMKO WKM 170 is better on 6 of 13 comparable points.
Who wins where
- REMKO WKM 170
- RP Handels AI-290-19-400V
Biggest differences
| Fact | WKM 170 | AI-290-19-400V |
|---|---|---|
| Refrigerant GWP | 675 | 3 |
| Refrigerant charge | 2.55 kg | 1.9 kg |
| COP A-7/W35 | 3.34 | 2.74 |
| COP A7/W35 | 5.06 | 4.36 |
| ISDE grant (NL) | 3,475 € | 3,925 € |
| Seasonal efficiency ηs 35 °C | 204 % | 183.4 % |
Score per area = position (0–100) relative to all 1350 models in this category; higher is better.
| Technical specifications | REMKOWKM 170 | RP HandelsAI-290-19-400V |
|---|---|---|
| Grants & market | ||
| SEAI Heat Pump System Grant | €14,500 | €14,500 |
| General | ||
| Type (source) | Air-to-water 1 | Air-to-water 1 |
| Performance | ||
| Rated output 35 °C | 13.96 kW 1 | 13.96 kW 1 |
| Rated output 55 °C | 12.9 kW 1 | 13.76 kW ✓ 1 |
| Efficiency | ||
| SCOP (35 °C) | 5.17 ✓ 1 | 4.66 1 |
| SCOP (55 °C) | 3.65 ✓ 1 | 3.61 1 |
| Seasonal efficiency ηs 35 °C | 204 % ✓ 1 | 183.4 % 1 |
| Seasonal efficiency ηs 55 °C | 143 % ✓ 1 | 141.3 % 1 |
| COP A7/W35 | 5.06 ✓ 1 | 4.36 1 |
| COP A2/W35 | 3.84 1 | – |
| COP A-7/W35 | 3.34 ✓ 1 | 2.74 1 |
| Noise | ||
| Outdoor unit sound power | 62.1 dB(A) 1 | 59 dB(A) ✓ 1 |
| Refrigerant | ||
| Refrigerant | R32 1 | R290 1 |
| Refrigerant GWP | 675 2 | 3 ✓ 2 |
| Refrigerant charge | 2.55 kg 1 | 1.9 kg ✓ 1 |
| Electrical | ||
| Max. power input | 5 kW 1 | 7.4 kW 1 |
| Connectivity & smart | ||
| SG Ready | Yes 1 | Yes 1 |
| Grants & market | ||
| ISDE grant (NL) | 3,475 € 2 | 3,925 € ✓ 2 |
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 28 Sept 2026
- ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 28 Sept 2026